How To Fix a Roper Washer that Filling When Not In Use

Why This Symptom Happens

A water inlet valve solenoid that stays partially energized or has debris lodged under its seat will leak water into the tub while the washer is off. A failed water level pressure switch or a clogged pressure hose can also send a false “water present” signal to the control board, which may keep the fill circuit active. Roper washers may display Error Code 19 (water in the tub while the washer is off or paused over 24 hours) when this occurs.

🚨 Repair Difficulty Tier

  • Difficulty Rating: Intermediate
  • Required Tools: 5/16-inch Nut Driver (hex mounting fasteners), 1/4-inch Nut Driver (hex bracket fasteners), Phillips #2 Screwdriver (cabinet and panel screws), Digital Multimeter (continuity and resistance testing)
  • Summary: The repair requires removing the rear or top panel to reach the inlet valve and pressure switch, and the work involves residual water and live electrical connections. Water supply and power must be fully isolated before any internal access.

🛠️ Step-by-Step Resolution Guide

Step 1: Preliminary & Visual Inspections

  • Unplug the washer from the wall outlet immediately.
  • Turn off both hot and cold water supply faucets at the wall.
  • Disconnect the inlet hoses at the back of the washer and check for debris or sediment in the hose screens.
  • Inspect the hoses for kinks, cracks, or bulges that could hide a leak.
  • Check the coin trap or hose connections at the wall for drips that may mimic internal filling.
  • Confirm the control knob or touchpad is not left in a fill or soak setting.

Step 2: Component Testing & Verification

  • Keep the washer unplugged and the water supply closed before testing any electrical part.
  • Set the digital multimeter to continuity or the 200-ohm resistance range.
  • Remove the inlet valve harness and measure each solenoid coil, where a reading near infinity indicates an open coil and a very low or shorted reading indicates a fault.
  • Remove the pressure switch hose from the tub and check it for water, air leaks, or blockage by blowing through it gently.
  • Test the pressure switch terminals with the multimeter, where the contacts should read open when the tub is empty.
  • Manually inspect the inlet valve plunger and diaphragm for debris or sticking while the washer is fully powered off.

Step 3: Replacement & Reset Process

  • Remove the rear panel with the Phillips #2 Screwdriver and disconnect the inlet valve wiring harness.
  • Loosen the valve bracket hex fasteners with the 1/4-inch Nut Driver and remove the faulty inlet valve.
  • Install the replacement valve, reconnect the water lines, and secure the bracket with the 5/16-inch Nut Driver.
  • Push all wire harness connectors firmly into place and route the harness away from moving parts before reassembling the panel.
  • Reconnect the power and water supply, then run a short test cycle to confirm the tub no longer fills while idle.
  • Clear Error Code 19 by following the Roper diagnostic mode procedure in the service manual, then verify no codes reappear.

📦 Parts, Labor, and Budget Estimates

  • Required Components: Hot/cold water inlet valve assembly (most likely), water level pressure switch (if the test fails), pressure hose (if cracked or blocked)
  • Average Component Price: $25 – $90 USD for an inlet valve, $20 – $60 USD for a pressure switch
  • Estimated Labor Hours: 1.0 – 1.5 hours
  • Total Estimated Budget: $120 – $275 USD

Need troubleshooting help for a different issue? Return to our complete Roper Appliance Repair Index.